A-A-53099
TABLE II. Classification of Defects
Categories |
Defects |
Major 101 102 103 104 |
Any component part missing, broken, or otherwise unusable. Exposed edge not free of burrs or sharpness. Two sets of instructions not furnished with unit. Storage unit not packaged as a single unit. |
Minor 201 202 |
Finish not free of chips, cracks, scratches and other appearance defects. Unit not clean. |
Tests. The rack-bin assembly shall be completely assembled I its operating configuration and tested to determine compliance with this description. Testing shall include the following:
The fully assembled rack shall be tested with the load of 1,620 pounds. Failure to be free from wobble and distortion shall constitute a major defect.
The fully assembled rack shall be tested with an empty load. Failure to be free from wobble and distortion shall constitute a major defect.
Each storage bin on the assembled rack shall be tested to support a load of 15 pounds each. Any cracking or breaking of a bin shall constitute a major defect.
Metric products. Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units, providing they fall within the tolerance specified using conversion tables contained in the latest revision of Federal Standard No. 376, and all other requirements of this document are met.
If a product is manufactured to metric dimensions and those dimensions exceed the tolerances specified in the inch/pound units, a request should be made to the contracting officer to determine if the product is acceptable.
The contracting officer has the option of accepting or rejecting the product.