Tests. Tests shall be conducted to determine compliance with specification requirements. Where feasible, the same sample shall be used for the determination of two or more test characteristics.
Sampling. Sampling for examination shall be conducted in accordance with MIL-STD-105 and table I. the unit of product for sampling purposes shall be patient utility kit as specified in this description.
TABLE I. Sampling for examination.
|
Inspection level |
AQL (defects per hundred units) |
For visual examination |
||
Major defect |
II |
1.01 |
Total defects (Major and minor combined) |
II |
4.0 |
For dimensional examination |
S-1 |
2.5 |
Examination. The patient utility kit shall be examined to determine compliance with all requirements contained in this specification.
Classification of defects. Examination shall be conducted in accordance with the classification of defects listed in table II. Examination shall not be restricted to the classified possible defects below.
TABLE II. Classification of Defects
Classification |
Defect |
Major |
|
101 |
Utility Kit not complete with all components. |
102 |
Any component not properly secured in storage tray. |
103 |
Any component cracked, broken, leaking, or otherwise unusable |
Minor |
|
201 |
Utility kit not free of dirt or loose debris. |