A-A-51675B
Defects.
Holder is not fabricated of mill anodized plain aluminum material. |
Holder is not designed for easy opening. |
Holder does not have a 3/4 inch holding capacity. |
Holder does not have two clips inside front cover to hold correspondence. |
Holder does not have a spring loaded clip inside front cover to hold addressograph plates. |
Holder does not have extension hangers. |
Top torsion springs do not operate easily and smoothly. |
Holder not free from warping, sharp edges, pitting, scratches, or stains. |
Sampling for tests. Sampling for tests (dimensional) shall be conducted in accordance with MIL-STD-105, with an AQL of 2.5 (percent defective) and an inspection level of S-1. The unit of product for test purposes shall be one clinical chart holder.
a. First article. Where a first article sample is required, all tests shall be performed on that unit.
b. Acceptance testing. When a first article sample has not been required, one unit shall be subjected to the performance test specified herein. If a test article sample has successfully passed all tests, performance test shall not be required at acceptance.
Metric products. Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units, providing they fall within the tolerance specified using conversion tables contained in the latest revision of Federal Standard No. 376, and all other requirements of this document are met.
If a product is manufactured to metric dimensions and those dimensions exceed the tolerances specified in the inch/pound units, a request should be made to the contracting officer to determine if the product is acceptable.
The contracting officer has the option of accepting or rejecting the product.