A-A-51021A
The soap dish shall be capable of accepting a bar of soap measuring 4 inches long and 2-1/2 inches wide. Along the inside bottom of the holder, there shall be raised ridges to allow for drainage. Molded clips to attach to wash basin shall be acceptable.
Each kit components shall be free from objectionable odor, sharp edges, cracks, holes, or thin areas. The edges of all items shall be smooth or rounded to preclude injury to patients. All items shall rest evenly on a flat surface without rock or wobble.
Finish of all components shall be free of scratches, mars, or chips. All components shall be clean and free of grease, oil, dirt or other foreign matter. All components shall be packaged ready for use in a closed transparent polyethylene bag which shall be a minimum of 0.0025 inch thick.
The wash basin, emesis basin, soap holder, and tumbler shall not show evidence of cracks, chips, or other defects when dropped from a height of 36 inches as specified.
All kit components shall be capable of being washed in hot water. Each components, when filled with water at 145oF plus or minus 5oF and placed on a flat surface for one hour, shall not show evidence of leakage, cracking, warping, or other deformation.
Workmanship. The patient utility kit shall be free from defects which detract from its appearance or impair its serviceability.
Unit. Each (EA). One patient utility kit, as specified, constitutes one unit.
Quality Assurance Provisions.
Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements.